Monitor de carga de motor Unipower HPL, 100 → 400 V ac, 40 A

Código de producto RS: 745-8030Marca: UnipowerNúmero de parte de fabricante: HPL500
brand-logo
Ver todo de Protección de Motores

Documentos Técnicos

Especificaciones

Corriente Nominal

40 A

Componente de Protección del Motor

Load Monitor

Tensión de Alimentación

100 → 400 V ac

Serie

HPL

Salida

3

Sensing Type

Transformador de Corriente

Tipo de carcasa

Montaje en pared, carril DIN

Control Voltage

100 → 575 V

País de Origen

Denmark

Datos del producto

Monitor de carga de motor digital HPL500

The HPL500 replaces the HPL420 and also incorporates many new features, however it has been designed so that users of the HPL420 will be familiar with its set-up procedure. The display is used as a reference enabling true motor load, trip levels and all other variables to be displayed and programmed quickly and accurately using only three push buttons. For two speed motor applications an input allows the application to select the active limit
The HPL500 is usually mounted in the motor control panel and is connected to a convenient point on the motor supply (before Inverter - if used).
Therefore no external field wiring or sensors in the equipment are necessary. In addition to displaying true motor power in real time the units capture and, on demand, display the instantaneous minimum and maximum power levels to assist in setting up trip limits and fault diagnosis. The HPL500 features a current feed-through tube for measuring continuous motor currents up to 40 amps, (27.7kW at 3 x 400vac). Therefore no Current Transformer is required unless the motors continuous current exceeds 40A.
A specially designed power supply (Patent Pending) allows the motor voltage to be programmable from 100 – 400vac single phase and 100 – 575vac 3-phase making the HPL500 suitable for world-wide use.
The 0(4)-20ma analogue output, which is proportional to motor load, can be scaled to the range of measured power and can be inverted for use in closed loop control systems.

Mide la carga real del motor en kW (√3 x I x V x Cosφ) y dispone de un display digital de kW% y kW, y disparos programables para eventos de exceso o defecto de carga
Puede programarse para calcular la potencia de salida el eje P2 si es necesario
Protege el equipos de daños causados por el funcionamiento del motor contra un atasco, bloqueo o bajo carga
Se utiliza en procesos para activar acciones cuando se alcanzan niveles de carga predeterminados (control de punto final)
Se incorporan tres temporizadores de retardo digitales, programables de 0,1-99,9 segundos para calcular los eventos de exceso y falta de potencia de corta duración y los transitorios de arranques de motor que pueden causar disparos molestos
Dos relés de salida son individualmente programables, alarmas de exceso o falta de carga
También se puede programar el estado del relé de salida (NA o NC)
Todos los ajustes están protegidos por bloqueo de teclas
Se utiliza para la protección de exceso/defecto de carga de: bombas (funcionamiento en seco, válvula cerrada), ventiladores (correa rota, amortiguador cerrado), transportadores (tornillo y correa), pantallas de separación, maceradores, rasquetas, actuadores mecánicos (cajas reductoras, cadenas)
Adecuado también para control de procesos, entrada PLC y SCADA

Approvals

CE, UL and GOST-R

Volver a intentar más tarde

Vuelva a verificar más tarde.

Volver a intentar más tarde

$ 873.094

Each (Sin IVA)

$ 1.038.982

Each (IVA Incluido)

Monitor de carga de motor Unipower HPL, 100 → 400 V ac, 40 A

$ 873.094

Each (Sin IVA)

$ 1.038.982

Each (IVA Incluido)

Monitor de carga de motor Unipower HPL, 100 → 400 V ac, 40 A
Volver a intentar más tarde

Documentos Técnicos

Especificaciones

Corriente Nominal

40 A

Componente de Protección del Motor

Load Monitor

Tensión de Alimentación

100 → 400 V ac

Serie

HPL

Salida

3

Sensing Type

Transformador de Corriente

Tipo de carcasa

Montaje en pared, carril DIN

Control Voltage

100 → 575 V

País de Origen

Denmark

Datos del producto

Monitor de carga de motor digital HPL500

The HPL500 replaces the HPL420 and also incorporates many new features, however it has been designed so that users of the HPL420 will be familiar with its set-up procedure. The display is used as a reference enabling true motor load, trip levels and all other variables to be displayed and programmed quickly and accurately using only three push buttons. For two speed motor applications an input allows the application to select the active limit
The HPL500 is usually mounted in the motor control panel and is connected to a convenient point on the motor supply (before Inverter - if used).
Therefore no external field wiring or sensors in the equipment are necessary. In addition to displaying true motor power in real time the units capture and, on demand, display the instantaneous minimum and maximum power levels to assist in setting up trip limits and fault diagnosis. The HPL500 features a current feed-through tube for measuring continuous motor currents up to 40 amps, (27.7kW at 3 x 400vac). Therefore no Current Transformer is required unless the motors continuous current exceeds 40A.
A specially designed power supply (Patent Pending) allows the motor voltage to be programmable from 100 – 400vac single phase and 100 – 575vac 3-phase making the HPL500 suitable for world-wide use.
The 0(4)-20ma analogue output, which is proportional to motor load, can be scaled to the range of measured power and can be inverted for use in closed loop control systems.

Mide la carga real del motor en kW (√3 x I x V x Cosφ) y dispone de un display digital de kW% y kW, y disparos programables para eventos de exceso o defecto de carga
Puede programarse para calcular la potencia de salida el eje P2 si es necesario
Protege el equipos de daños causados por el funcionamiento del motor contra un atasco, bloqueo o bajo carga
Se utiliza en procesos para activar acciones cuando se alcanzan niveles de carga predeterminados (control de punto final)
Se incorporan tres temporizadores de retardo digitales, programables de 0,1-99,9 segundos para calcular los eventos de exceso y falta de potencia de corta duración y los transitorios de arranques de motor que pueden causar disparos molestos
Dos relés de salida son individualmente programables, alarmas de exceso o falta de carga
También se puede programar el estado del relé de salida (NA o NC)
Todos los ajustes están protegidos por bloqueo de teclas
Se utiliza para la protección de exceso/defecto de carga de: bombas (funcionamiento en seco, válvula cerrada), ventiladores (correa rota, amortiguador cerrado), transportadores (tornillo y correa), pantallas de separación, maceradores, rasquetas, actuadores mecánicos (cajas reductoras, cadenas)
Adecuado también para control de procesos, entrada PLC y SCADA

Approvals

CE, UL and GOST-R